Detail Electrician S Multimeter With Non-Contact Voltage Fluke Model : 117
Electrician' s Multimeter with Non-Contact voltage Fluke Model : 117
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
11 A, 1000 V FAST Fuse ( Fluke PN 803293)
Display
Digital: 6, 000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 ° C to + 50 ° C
Storage Temperature
-40 ° C to + 60 ° C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
DC volts
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.00 V / 0.1 V
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz)
4.0 % + 3 ( 500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
2.0 % + 3 ( 500 Hz to 1 kHz)
AC volts1 true-rms
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
2.0 % + 3 ( 500 Hz to 1 kHz)
Continuity
Range: 600 &
Resolution: 1 &
Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer.
Ohms
Range/ Resolution: 600.0 & / 0.1 &
Range/ Resolution: 6.000 k& / 0.001 k&
Range/ Resolution: 60.00 k& / 0.01 k&
Range/ Resolution: 600.0 k& / 0.1 k&
Range/ Resolution: 6.000 M& / 0.001 M&
Accuracy: 0.9 % + 1
Range/ Resolution: 40.00 M& / 0.01 M&
Accuracy: 5 % + 2
Diode Test
Range/ Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/ Resolution: 1000 nF / 1 nF
Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F
Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F
Range/ Resolution: 9999 ¼ F / 1 ¼ F
Range/ Resolution: 100 ¼ F to 1000 ¼ F
Accuracy: 1.9% + 2
Range/ Resolution: > 1000 ¼ F
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 ¼ F
Accuracy: 10% + 2 typical
AC amps true-rms ( 45 Hz to 500 Hz)
Range/ Resolution: 6.000 A / 0.001 A
Range/ Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/ Resolution: 6.000 A / 0.001 A
Range/ Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A continuous overload for 30 seconds max
Hz ( V or A input) 2
Range/ Resolution: 99.99 Hz / 0.01 Hz
Range/ Resolution: 999.99 Hz / 0.1 Hz
Range/ Resolution: 9.999 Hz / 0.001 Hz
Range/ Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2
Tampilkan Lebih Banyak