Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Electrician' s Multimeter with Non-Contact voltage Fluke Model : 117

Electrician s Multimeter with Non-Contact voltage Fluke Model : 117

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
4 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Electrician S Multimeter With Non-Contact Voltage Fluke Model : 117

Electrician' s Multimeter with Non-Contact voltage Fluke Model : 117 Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse ( Fluke PN 803293) Display Digital: 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz) 4.0 % + 3 ( 500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range: 600 & Resolution: 1 & Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy: 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy: 5 % + 2 Diode Test Range/ Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/ Resolution: 1000 nF / 1 nF Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F Range/ Resolution: 9999 ¼ F / 1 ¼ F Range/ Resolution: 100 ¼ F to 1000 ¼ F Accuracy: 1.9% + 2 Range/ Resolution: > 1000 ¼ F Accuracy: 5% + 20% LoZ capacitance Range: 1 nF to 500 ¼ F Accuracy: 10% + 2 typical AC amps true-rms ( 45 Hz to 500 Hz) Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A continuous overload for 30 seconds max DC amps Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A continuous overload for 30 seconds max Hz ( V or A input) 2 Range/ Resolution: 99.99 Hz / 0.01 Hz Range/ Resolution: 999.99 Hz / 0.1 Hz Range/ Resolution: 9.999 Hz / 0.001 Hz Range/ Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2
Tampilkan Lebih Banyak