Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Earth Clamp Testers / Grounding Tester / Megger Tanah / Kyoritsu MODEL 4200

Earth Clamp Testers / Grounding Tester / Megger Tanah / Kyoritsu MODEL 4200

Update Terakhir
:
21 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
134 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Earth Clamp Testers / Grounding Tester / Megger Tanah / Kyoritsu MODEL 4200

Earth Clamp Testers / Grounding Tester / Megger Tanah / Kyoritsu MODEL 4200 • The earth resistance from 0.05 to 1200© can be measured without the auxiliary earth spikes. ( The Multiple Earthing System.) • True RMS Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A • Noise Check Function A function to detect current, which effects on an earth resistance measurement and display " NOISE" mark on the LCD. • Memory function Save and display up to 100 measurement data. • Data hold function / Buzzer function / Back light function • Compliant with Safety Standards of IEC 61010-1 : CAT.IV 300V Pollution degree2 Note: A single earthing can not be measured. ( Only for Multiple Earthing System) Function Range Resolution Measuring range Accuracy Earth resistance Auto range 20© 0.01© * 0.00~ 20.99© | ± 1.5% ± 0.05© 200© 0.1© 16.0~ 99.9© | ± 2% ± 0.5© 100.0~ 209.9© | ± 3% ± 2© 1200© 1© 160~ 399© | ± 5% ± 5© 400~ 599© | ± 10% ± 10© 10© 600~ 1260© --- AC current ( 50Hz / 60Hz) Auto range 100mA 0.1mA 0.0~ 104.9mA | ± 2% ± 0.7mA 1000mA 1mA 80~ 1049mA | ± 2% 10A 0.01A 0.80~ 10.49A 30A 0.1A 8.0~ 31.5A Operating system Earth resistance function : Constant voltage injection, Current detection, ( Frequency : Approx.2400Hz) Dual Integration AC current function : Successive Approximation Over-range indication " OL" is displayed when input exceeds the upper limit of a measuring range Response time Approx.7 seconds ( Earth resistance) Approx.2 seconds ( AC current) Sample rate Approx. 1 times per second Power source DC6V : R6P ( sizeAA manganese battery) × 4pcs, or LR6 ( sizeAA alkaline battery) × 4pcs Current consumption Approx. 50mA ( max. 100mA) Measurement time Approx. 12 hours ( when R6P is used) Approx. 24 hours ( when LR6 is used) Auto power-off Turns power off about 10 minutes after the last button operation. Applicable standards IEC 61010-1 : 2001 ( CAT.IV 300V Pollution degree2) Withstand voltage AC5320Vrms / 5 seconds Between the Transformer jaws fitted parts and Case enclosure ( except for jaws) Conductor size Approx. 32mm max. Dimension 246( L) × 120( W) × 54( D) mm Weight Approx. 780g ( including batteries) Accessories Battery R6P : 4pcs Instruction manual : 1pc 8304 ( Resister for operation check : 1pc) 9128 ( Hard case : 1pc) • Crest factor < 3 ( 50Hz / 60Hz, peak value shall not exceed 60A) * 4 counts or less are corrected to 0
Tampilkan Lebih Banyak